[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Brocade Fabric Help
- Subject: Brocade Fabric Help
- From: tmccleve at voonami.com (TJ McCleve)
- Date: Thu, 30 Jun 2016 21:28:10 +0000
- In-reply-to: <1217501659.6466.1467315681031.JavaMail.mhammett@ThunderFuck>
- References: <2108070581.6455.1467315622055.JavaMail.mhammett@ThunderFuck> <1217501659.6466.1467315681031.JavaMail.mhammett@ThunderFuck>
I would suggest opening a TAC to get the full details on why it?s happening if the root cause not readily apparent. Typically remediating a these types of mismatches entails copying the default config to startup (triggers a reload) and rejoining the fabric.
On 6/30/16, 1:41 PM, "NANOG on behalf of Mike Hammett" <nanog-bounces at nanog.org on behalf of nanog at ics-il.net> wrote:
>I asked on the Brocade forum, but it's largely been crickets there. I hoped someone here would have an idea.
>
>One switch says: 23 Te 12/0/24 Up ISL segmented,(ESC mismatch, Distributed Config DB)(Trunk Primary)
>The other switch says: 23 Te 54/0/24 Up ISL segmented,(ESC mismatch, Distributed Config DB)(Trunk Primary)
>
>I saw that means, "The DCM Configuration DB is different on both the ends of ISL," but I have no idea how to resolve that.
>
>
>VDX-6720s running 4.1.3b.
>
>
>
>
>-----
>Mike Hammett
>Intelligent Computing Solutions
>http://www.ics-il.com
>
>
>
>Midwest Internet Exchange
>http://www.midwest-ix.com
>
>