[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Brocade Fabric Help
- Subject: Brocade Fabric Help
- From: fred at web2objects.com (Fred Hollis)
- Date: Thu, 30 Jun 2016 23:55:46 +0200
- In-reply-to: <1217501659.6466.1467315681031.JavaMail.mhammett@ThunderFuck>
- References: <1217501659.6466.1467315681031.JavaMail.mhammett@ThunderFuck>
Hello Mike,
Running a few larger Brocade VDX fabrics here...
In case of that message, there is no other option not to reset that
specific new switch and then re-join the device. I had that a few times,
too.
It happens when you already did some configuration changes on the new
switch and the older fabric members weren't aware of that.
On 30.06.2016 at 21:41 Mike Hammett wrote:
> I asked on the Brocade forum, but it's largely been crickets there. I hoped someone here would have an idea.
>
> One switch says: 23 Te 12/0/24 Up ISL segmented,(ESC mismatch, Distributed Config DB)(Trunk Primary)
> The other switch says: 23 Te 54/0/24 Up ISL segmented,(ESC mismatch, Distributed Config DB)(Trunk Primary)
>
> I saw that means, "The DCM Configuration DB is different on both the ends of ISL," but I have no idea how to resolve that.
>
>
> VDX-6720s running 4.1.3b.
>
>
>
>
> -----
> Mike Hammett
> Intelligent Computing Solutions
> http://www.ics-il.com
>
>
>
> Midwest Internet Exchange
> http://www.midwest-ix.com
>
>