[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[ale] Confusing RAID Performance
On 2/2/11 2:15 PM, scott wrote:
> Remember that RAID6 is slower than RAID5. RAID5 calculates the parity
> once. RAID6 does it twice. This is to make sure that you have parity
> protection incase you drop a drive. I would only recommend RAID6 on
> large drives (1TB or larger).
I sure wouldn't. For >=~1TB drives, the probability of having an
unrecoverable read error among all the drives at recover time starts
becoming significant. Sure, you can use it - as long as a restore from
tape, etc. is an acceptable fallback if you can't rebuild after a drive
replacement.